This paper offers a selection and setting guide for ground fault detection on noncompensated overhead power lines. Examining also the different plotsof rotor angle versus time for the different faults at. Mutual impedance in parallel lines protective relaying and fault. Linetoline ll fault doublelinetoground llg fault three phase 3p fault 3.
Simulation study of single linetoground faults on rural. In single line earth fault, one line undergoes earth fault. To analyze a slg fault, denote fault currents in phases a, b, and c as i af, 0, and 0 observe we are not changing the impedance matrix but rather adding a. Pdf double phase to ground fault classification and fault distance. A single linetoground lg fault is one of the most common faults and experiences show that 7080 percent of the faults that. Unsymmetrical fault calculations part 24 double linetoground fault problem a 25 mva, 11 kv, 50 hz and threephase generator has z1 j0. Learning outlinelearning outline symmetrical components theorysymmetrical components theory sequence impedance.
Linetoground fault article about linetoground fault. This fault will occur when any one line is in contact with the ground. University format manual, and that this project is suitable for shelving in the library and credit is to be. Single line to ground fault analysis electrical concepts. This voltage usually causes flashover between the phase and the ground of the line creating an arc. Now, lets suppose that a restricted fault upstream fault occurs in the plant. Linetoline fault a line to line fault or unsymmetrical fault occurs when two conductors are short circuited.
Because of that, each ground fault current in an hv network has at. Abstractmarshall steam station is a fourunit, coalfired generating. For this situation, the use of separate ground fault relaying is required. The expressions for voltage drop in the lines may be written as a single vector expression. The values of inductive reactance of these circuits are proportional to the. He recalled that intentionally and maliciously planted banana trees within the power line corridor caused a linetoground fault that tripped high voltage lines and led to a blackout across the entire zamboanga peninsula, including areas served by distribution utilities zamsureco i, zamsureco ii, zaneco, zamcelco, moelci i, moelci ii, and parts of laneco. But you say you dont want to use a thirdparty component. Application description the settings of g and gext protections must guarantee the discrimination. Design and application considerations for each problem area are given to aid in setting the relay elements correctly. The figure below shows the three types of symmetrical faults occurred due to the short circuit conditions, namely phase or line to ground lg fault, phase to phase ll fault and double line to ground llg fault. Threephasetoground fault and its impact on voltage. To illustrate the independence of symmetrical components in balanced networks, consider the transmission line illustrated back in figure 20 of installment 3 of these notes. Abstractwhen two or more lines are running parallel to each other.
Classification of single line to ground faults on double. Load, line, generator, t ftransformer fault analysis. For doublelinetoground faults or linetoline faults, on phases b and c, postfault. Double linetoground faults with a double linetoground dlg fault two line conductors come in contact both with each other and ground. Find the line currents and the linetoline voltages when a double linetoground fault occurs at the terminals of the generator described in single linetoground fault example. Lighting strokes cause most faults on highvoltage transmission lines producing a very high transient that greatly exceeds the rated voltage of the line. In transmission line faults, roughly 15% 20% are asymmetric double linetoground. Avoiding ground fault problems when designing for multiple low voltage sources by mike pintar, ge lv switchgearswitchboard application engineer. Charles kim, lecture notes on fault detection and location in distribution systems, 2010. Further, earth fault and line to earth fault means same thing. Assuming a coretype transformer, a phasetoground fault can produce more fault current than a threephase fault when the fault is at the bus. In transmission line faults, roughly 65% 70% are asymmetric linetoground faults.
Lecture notes eee 360 michigan technological university. This could be caused by the source 1 ground connection having a higher impedance than source 2 ground. Single linetoground faults account for about 90% of the. General fault admittance method linetoground faults in. The decay of the transient condition, until it merges into steady state. Currently, there are thre e me thods for achieving lowvoltage arcing groundfault protection. Pdf on aug 29, 2009, anamika jain and others published double phase to. Fault analysis in fourwire distribution networks semantic scholar. In extreme cases, tripping at the grid and terminal of the transmission line must. Suppose the phase a is connected to ground at the fault point f as shown in a figure below.
Create pdf files without this message by purchasing novapdf printer. Thus for faulted phase, in case of single line to ground fault, we can write. I a, i b and i c are the current and v a, v b and v c are the voltage across the three phase line a, b and c respectively. Assume that the generator was unloaded and operating at. Pdf double phase to ground fault classification and. These topics are presented in four separate parts, part 1 through part 4. In the figure shown below shows a three phase system with a linetoline fault phases b and c. Unbalanced and double line to ground fault detection of. Shows the matlab simulation diagram of double line to ground fault and three phase unbalance fault incorporated in the three phase vsi fed induction motor drive. The magnitudes and waveforms of the transients are determined at three different locations of the transmission system i. Unsymmetrical faults and symmetrical components chegg. If there were no any grounded neutral, no fault current would have been flow.
Therefore, a linetoground fault on an odd phase, say on the b or c phase, poses no difficulties and is easily accommodated. Double line to ground fault llg fault single line to ground fault is the most frequently occurring fault 60 to 75% of occurrence. What is the difference between earth fault and single line. White paper double ground fault protection implementation. Firstly the gext protection is activated and, after. Field experience with detecting an arcing ground fault on. The ll fault is placed between lines b and c so that the fault be symmetrical with respect to the reference phase a which is unfaulted. Method of fault location for double linetoearth faults. First thing which must be understood at this point, that fault current is completing its path through the grounded neutral. Ground fault current distribution when a ground fault. The fault impedance of the line is z f since only phase a is connected to ground at the fault, phase b and c are open circuited and. Ground fault location is discussed, as is the implication of.
A single line to ground fault location method employing wavelet fuzzy neural network to use postfault transient and steadystate measurements in the distribution lines of an industrial system is proposed in 12, it does not classify the classification of single line. Double line to ground fault is created in the above system between 2 and 3 seconds where as three phase unbalanced fault is created between 7 and 8 seconds. Earth fault may be single line to earth fault or double line to earth fault. Pdf slgsinglelinetoground fault location in nugsneutral. Sequence connections for a linetoline fault sequences. The setting guide offers support in selecting the proper ground fault. Double phase to ground fault classification and fault distance location of double circuit transmission lines using ann conference paper pdf available august 2009 with 591 reads how we measure. This is the most severe fault, followed by the double line to ground fault whose cct is 0. Faults in threephase power systems are short circuits. For the protection of transmission line we place the circuit.
Avoiding ground fault problems when designing for multiple. This paper presents the results of linetoground faults on the reference and odd phases of a simple power system obtained using the general fault admittance method. The transmission line fault analysis helps to select and develop a better for protection purpose. Charles kim, lecture notes on fault detection and location in. Post fault voltages and currents from both substation terminals were used as the. System model stability studies of a single line, double. Fault location in case of double linetoearth faults dlef at the same line is implemented by usage of impedance measuring elements ime which measure the impedance of phase circuits. Get free shipping on qualified ground fault interrupter, circuit breakers products or buy online pick up in store today in the electrical department. The dapper comprehensive fault analysis program provides a network solution of threephase, singleline to ground, lineto line, and double line to ground fault currents. A solar array is a current source which means it can only produce a limited amount of. Faults occur when equipment insulation fails, due to system overvoltages, lightning, contamination or other mechanical causes. When two lines touch each other and also touch the ground, the fault is called a double linetoground fault. Name the various unsymmetrical faults in a power system. During a ground fault in a hv network the ground fault current leaves phase line conductor and for returning to the feeding sources uses all available paths, including those that are not foreseen for this purpose.